Solidose Family
|
The Solidose family (Solidose 300, 308 & 400) is a user friendly dose and dose rate family of meters for service and quality control of X-ray equipment. It features built-in applications to simplify basic measurement needs. The Solidose is easy to use with large buttons and an informative display. The Solidose can also be interfaced to any type of computers for collection of data. The main feature of the Solidose 400 is the use of both solid state detectors and ion chambers.
|
|

Solidose 308
with R100 dose detector
Solidose 300 with R100 dose detector
Solidose 400 with Magna ionization chamber
|
- A single measuring range covering
more than six decades (>120 dB).
- Built in applications such as HVL
and reproducibility.
- Automatic Detector Identification
(ADI) system, fully compatible with PMX-III (not Solidose 308).
- RS-232 computer interface with software
(WinRAD).
- Battery operated or external power
supply.
- Possible to connect other solid
state detectors from RTI, using ADI system (not Solidose 308)
- Can be used together with BNC/Banana
type ion chambers (optional, only Solidose 300/400).
- Both use of Solid state detectors
and ion chambers (only Solidose 400).
- Bias voltage is adjustable by the
user (keypad), 100 - 300 V (only Solidose 400).
- Ion chamber adapter, female BNT
bayonet triaxial (optional, only Solidose 400).
Main Features
of the Solidose Family
- Dose and dose rate
- Radiography, CT, and Mammography
- Input dose rate to image intensifier
- Reproducibility
- HVL
- Relative mAs
- Dose/frame
- Ratio
|
Optional (not Solidose 308)
Light measurements can be made with the L100 light detector, and mAs
measurements with the MAS-1, MAS-2, and MAS-3. For the Solidose 400
different ion chambers for radiography, CT, and scatter measurements
are available. All chambers with BNT (bayonet triaxial) or TNT (thread
triaxial) connectors can be used.
Four Different Configurations of the Solidose 308
Solidose 308
is availbale with only with one of four beam qualities. The Solidose
308 is a cost effective alternative for everybody that need a simple
and easy to use dose and rate meter.
Solidose
308 A - For heavy
filtred beams, for example input dose to the I.I. Reference point
at 70 kV/23 mm Al.
Solidose 308 B -
For standard radiogrpahy. Reference point at 70 kV/3 mm Al.
Solidose 308 C -
For film dose mammography. Reference point at 28 kV/2 mm Al + 30
µm Mo.
Solidose 308 D -
For skin dose mammography. Reference point at 28 kV/30 µm Mo.
|
Solidose 300: Accessories |
O = Optional, S = Standard
O* = ADP-3
required
|
Solidose 308: Accessories |
O = Optional, S = Standard
|
Solidose 400: Accessories |
O = Optional, S = Standard
|
|