News

 
  1. Public Holiday and Changed Opening Hours

    16 May 12 Between 17–18 May RTI Headquarter is closed.
    RTI Inc is open as usual.

  2. New Software Release – 2012.05A

    11 May 12 Piranha and Barracuda Latest Update

    Released: May 11, 2012

    Ocean: 2012.05.09.82
    QABrowser: 4.2B
    oRTIgo: 6.5A
    CT Dose Profile Analyzer: 4.1A
    Firmware: 2012.2A

  3. Mammo12

    One Shot HVL for Mammography

    07 May 12 One shot HVL for mammography is now available to all new Piranhas of version 2 or higher.
    One shot HVL is possible both if you are using Ocean or QA Browser, with or without compression paddle.

    All Piranhas (version 2 or higher), which are in for re-calibration, will get the one shot HVL feature.

  4. Time for Calibration - Schedule Yours Now

    06 May 12 Please take five minutes to schedule your coming calibration with the RTI Service department.

Show all news

Light Probe

Light Probe

Measures the Brightness on Monitors with the Same Spectral Response as the Human Eye

The Light Probe is designed to comply with the needs for QA in modern X-ray departments. With a monitor and a lux adapter the Light Detector measures the brightness on monitors and film viewing boxes, and the ambient light in the room. The Light Probe has the same spectral response as the human eye. That makes it reliable for all different types of measurements, independent of the light source. The spectral response complies with the CIE curve.

The Barracuda Light Probe

The Barracuda Light Probe has the same spectral response as the human eye. That makes it reliable for all different types of measurements, independent of the light source. The spectral response complies with the CIE curve. To use the Barracuda Light Probe the Barracuda must have an electrometer module. Recommended model is EMM-BiasW.

The Piranha Light Probe

The Light Probe supports the Piranha ADI (Automatic Detector Identification) system. All information regarding the Probe is stored in a memory inside the probe. When connected, the Piranha automatically identifies the probe and makes all necessary adjustments without any need for interaction from the user. The Piranha ADI system also gives full interchangeability of probes between different Piranha systems using the same type of probes.

 

 


 

 

Specifications with the Piranha
Type  
L100B
Spectra Response 
CIE Photopic
Acceptance angle


Lux adapter  180° (Cosine)

Monitor adapter Ø 7 mm
Connector 
Hirose with built-in ADI
Monitor, viewing box


Range  0.03-72000 cd/m2

Inaccuracy  ±5 % or 0.006 cd/m2
Ambient light


Range  0.01-24000 lx

Inaccuracy  ±5 % or 0.002 lx

 

Specifications with the Barracuda
Type  
L100B
Spectra Response 
CIE Photopic
Acceptance angle


Lux adapter  180° (Cosine)

Monitor adapter Ø 7 mm
Connector 
LEMO Triaxial
Monitor, viewing box


Range  0.03-72000 cd/m2

Inaccuracy  ±5 % or 0.006 cd/m2
Ambient light


Range  0.01-24000 lx

Inaccuracy  ±5 % or 0.002 lx

Article Nr (with Piranha): 9730007-00
Article Nr (with Barracuda): 9730008-00

 
 

Please enter your user name and password below.

If you are the proud owner of a Barracuda, Piranha, or Nova you just have to enter your serial number as the user name and leave the password box empty.