News

 
  1. Receive Higher Accuracy when Measuring CTDIw

    06 Sep 10 RTI strongly recommends the 1-point method to be used for CTDIw measurements with the CT Dose Profiler. The method saves time and gives a higher accuracy than the 5 point method, either using a pencil ion chamber or the CT Dose Profiler.

  2. Decotron – New Distributor in Norway

    05 Sep 10 We welcome our new Norwegian distributor, Decotron, to our RTI Team.

  3. Meet Us at RPM in Bulgaria

    01 Sep 10 RTI will be at RPM in Bulgaria together with our distributor – Ecomed Services – to show you the best from RTI Electronics, our X-ray multimeters Piranha and Barracuda that togehter with our powerful software gives you an extraordinary X-ray QA solution.

  4. assets/News/Juli-2010/_resampled/SetWidth190-South-2.jpg

    RTI Electronics Strengthening its Position in South America

    23 Jul 10 We are now pleased to present three new distributors in South America.

  5. assets/News/Juli-2010/_resampled/SetWidth190-Picture-T20-034.jpg

    Important Solid State Detector Accessories by RTI Electronics

    23 Jul 10 If you own an RTI Piranha or Barracuda multi-meter, you may want to consider adding two special solid state detectors specially developed by RTI Electronics.

  6. EDGE July 2010

    21 Jul 10 Newsletter from RTI Electronics, July issue 2010.

Show all news

MPD Holder (OPG)

MPD Holder (OPG)

Makes the OPG Positioning Easier

The Barracuda is ideal for measurement on panoramic (OPG) systems. The unique design of the Multi-Purpose Detector makes it very simple to use. The small detector area and the "MPD position check", a feature that makes it possible to verify the detector position, ensures more accurate and more reproducible results than with other devices. Panoramic Holder makes the positioning of the detectors very easy. The MPD Panoramic Holder can be fitted with magnets or adhesive tape. The holder comes with several bendable plates that can be used to fit "around corners" depending on the geometry of the panoramic (OPG ) system. Note that on some panoramic systems, magnets are not allowed or not possible to use, and the plates makes it easy to use adhesive tape instead.


To perform a measurement:
  1. Attach the holder and MPD.
  2. Select the "MPD Position Check" and make an exposure.
  3. Select "measure all".
  4. Make an exposure and get kVp, exposure time, dose, dose rate, HVL total filtration, and waveform. All in one exposure!

 

 
 

Please enter your user name and password below.

If you’re the proud owner of a Barracuda, Piranha, or Nova you just have to enter your serial number as the user name and leave the password box empty.