application notes

PPP = PowerPoint Presentation
Number Updated Title Size
Download (PDF) June 2008

"Evaluation of two thin CT dose profile detectors and a new way to perform QA in a CTDI head pahntom"

Master Thesis, Cederquist B.

1.7 MB
1-AN-52020-24 Jan 2008

"Explanation of different Beam Qualities and detector types in the Detector Manager"

This application note explains all about different beam qualities (BQ) and different detector types used in the Detector Manager Software..

191 kB
1-AN-52020-6 Dec 2007

"Measurement of scattered radiation"

This application note shows a practical example of measurement of scattered radiation based on the NCRP report no. 47. Measurements are performed with Piranha Dose Probe and R100B for Barracuda.

410 kB
1-AN-52020-4 Oct 2007

"Getting started with the CT-SD16 detector"

This application note explains step-by-step how you get started with your new CT-SD16 detector.

844 kB
2-AN-52020-7 June 2007

"Getting started with Favourites with the QABrowserr"

This application note explains how to use favourites with the QABrowser.

245 kB
1-AN-52020-16 Feb 2007

"kVp and time on a dental unitr"

This application note explains how to measure kVp and time on dental units. Especially the problem with preheat pulses is explained.

206kB
1-AN-52020-15a Dec 2006

"Bluetooth troubleshooting on PC for Piranha and Barracuda: using D-Link Bluetooth adapter"

This application note is the complete troubleshooting guide for the connection between Bluetooth on PC and the Barracuda or the Piranha. For D-Link Bluetooth adapter.

164kB
1-AN-52020-15b Dec 2006

"Bluetooth troubleshooting on PC for Piranha and Barracuda: using built-in Bluetooth"

This application note is the complete troubleshooting guide for the connection between Bluetooth on PC and the Barracuda or the Piranha. For PC with built-in Bluetooth.

152kB
Download (PDF) March 2006

"Measurements of Dose Profile and axial scans on CT and Scanning Mammography Units"

The technological developments in areas of CT and Mammography are increasing and bring new requirements on the instruments used for QA. By using a CT slice probe it is possible to actually see how the X-ray look like since it gives spatial and time information that is lacking when using ionization chambers.

119kB
1-AN-52020-14 Jan 2006

"Measurements of Total Filtration and kV with MPD and Barracuda"

This application note describes how to do measurements of the total filtration with the MPD and Barracuda using either the Palm software - the QABrowser
or the PC software - oRTIgo.

400kB
Download (PDF) Nov 2005 ”Development and evaluation of a new detector and software for measurements of CT dose profile, CTDI and CT tube current variation”, master thesis by Henrik Karlsson 1.1 MB
Download (PDF) March 2006 "The New CT Slice Detector, CT-SD16" 1.6 MB
Download (PDF) Nov 2005 "Real-time Solid State CT Dosimetry: Dose Profiles", summery of Session SSE17-01 given at RSNA 2004 28 kB
Download (PDF) Oct 2005 "Average Glandular Dose According to American and European Dose Protocols Using a Sectra MicroDose Mammography Unit" 113 kB
Download (PDF) Oct 2005 "A new Detector for Measurement of CT dose profile, CTDI and tube current variation" 167 kB
Download (PPP)

Download (PDF)
Oct 2005 "Sepcific Requirements When Performing When Performing Measurements of Dose, kVp and HVL on Scanning Mammography Systems" 9.3 MB

141 kB
Download (PDF) Feb 2005 A new detector for measurement of CT dose profile, CTDI and CT tube current variation 1.1 MB
1-AN-52020-1 July 2007 kVp measurements on GE AMX-4 with Barracuda
(the same is valid for Piranha)
362 kB
1-AN-52020-2 Feb 2005 How to measure ESAK and average glandular dose correctly with a Barracuda MPD or ionization chamber 760 kB

1-AN-52020-5

Hospital in Gothenburg

Feb 2005

Nov 2007

Optimal use of oRTIgo as a QA tool

oRTIgo session that is used as example in the application note.

960 kB
1-AN-52020-11 Feb 2005 Conversion tables between HVL and Total Filtration 132 kB
1-AN-52020-10 November 2004 Poster - Sectra MicroDose Measurements with Barracuda 1.5 MB
5-AN-52003-22 August 1999 kVp Correction Graph for 15 um Mo when using PMX III MAM Sensor - CA 5 13 kB
5-AN-52003-21 May 1999 Germanium detector and MCA Recommendations for Spectro-X 58 kB
5-AN-52003-20 Nov 1998 New kVp correction graphs Chapter 4.8.4. Radiographic - CA 1 74 kB
5-AN-52003-19 Sept 1998 Short Form Detector Selection Guide 19 kB
5-AN-52003-18 Sept 1998 Dosimeter Ranges for PMX-III Used with the Dose Detectors R25 and R100 47 kB
03-017/01 Dec 1996 Typical energy correction for R25 and R100 when measuring with Cu filtration 20 kB
5-AN-52003-16 Feb 1999 Extended graph for HVL-Total filtration conversion 262 kB
03-015/01 Sept 1996 Maximum mA settings at different kVp when using the R25 or R100 Dose Detector with PMX-III 22 kB
03-014/01 Sept 1996 Measurements of Luminance using the L100/M Light Detector 19 kB
03-013/01 March 1995 Measurements on a Siemens Mammomat 3000 Mammography Unit using the R100 Dose Detector 25 kB
03-012/01 March 1995 Measurements on a GE Senographe DMR Mammography unit using the R100 Dose Detector 26 kB
03-011/01 Nov 1994 Quality control of Automatic Exposure Control (AEC) system 17 kB
03-010/01 Sept 1994 Energy corrections factors for the R100 Solid state detector 32 kB
03-009/01 March 1994 HVL measurements using the PMX-III kit 321 kB
03-008/01 Feb 1994 HVL measurements with PMX-III and the MX detector on units with Tungsten target 38 kB
03-008/01 Feb 1994 HVL measurements with PMX-III and the MX detector on units with Tungsten target 38 kB
03-007/01 April 1993 Comparing PMX and Digi-X 17 kB
03-006/01 March 1993 HVL-Total filtration conversion in oRTIgo PMX 16 kB
03-005/01 Dec 1993 Energy correction factors for the MX detector 17 kB
03-004/01 July 1993 Measurements of kVp and dose on a Senographe DMR using PMX-III 32 kB
03-003/01 Sept 1992 Exporting data from oRTIgo to Microsoft Excel 18 kB
03-002/01 Aug 1992 Measuring mammographic HVL using the MX-detector 18 kB
03-001/01 Sept 1992 Comparison between the PMX-III dosimeter with MX solid state detector and different dosimeters with ion chambers 45 kB
01-002/02 March 1993 Measuring mammographic kVp in angled primary beams using the Digi-X 20 kB