  Barracuda X-ray Multimeter

The Barracuda is an "all-in-one" X-ray multimeter for all type of X-ray systems. It is the most versatile device available and it has set the standard for the latest generation of X-ray multimeters using solid-state technology. The Barracuda is accurate and easy to use. By automatically analyse the beam quality, the Barracuda can compensate measured values and directly display accurate results. The Barracuda is small and compact, the setup time is short, and it is easily transported in its carrying case.

All-In-One
The Barracuda is available in various configurations to meet different needs andrequirements. It doesn't matter if you need something for just radiography or you need something that can do "everything", there is always a suitable Barracuda.

 

The Barracuda is truly an "all-in-one" device:

  • kVp, time, dose, dose rate, pulses, pulse rate, dose/pulse, mA, mAs, HVL, total filtration and waveforms — All-In-One exposure
  • Radiography, fluoroscopy, mammography, dental, panoramic dental (OPG) and CT — All-in-one device
  • Work in the "new" way - use solid-state, automatic compensation gives you accurate results
    - or -
    Work in the "traditional" way - use ionization chambers. Your existing ionization chambers can be connected to Barracuda — All-in-one device

Automatic compensation
Dose and kVp measurements are very accurate due to the automatic compensation feature. The Barracuda analyses the beam quality for each exposure and applies necessary corrections before presenting the measured values. No need for correction graphs, correction factors or different look-up tables gives maximal ease-of-use.

Extremely sensitive
Many of today's X-ray system are using lower and lower doses to minimize radiation exposure to patients. Many QA devices are therefore not able to measure over the entire range of kVp and mA. The Barracuda detector is extremely sensitive and designed to measure even when the output from X-ray generator is very low. Minimum output for kV measurement is 0.025 mA, 45 kV at 50 cm.

Pulsed fluoroscopy
More and more X-ray systems with pulsed fluoroscopy are used. The Barracuda is designed to make it quick and easy to measure on such systems. The Barracuda analyzes the waveform automatically — pulse rate and dose/pulse are measured without any action from the user.

Built-in position check
If a non-invasive detector is tilted or incorrectly irradiated; measured values will be incorrect. The Barracuda has a unique feature — a detector position check — to help you to get more accurate and reproducible results. This is feature is especially important when measuring on CT, panoramic dental (OPG) and in other situations when it is difficult to position the detector. The position check makes it possible to verify, and if necessary adjust, the position of the Barracuda detector before starting the measurement. If the position is incorrect you will be asked to re-position the Barracuda detector. For smaller misalignments, a correction is automatically applied, and you can start the measurement.

Use of ionization chambers and other probes
The possibility to add electrometer functionality to the Barracuda allows the use of additional probes such as mAs probes, light detectors, CT probes and different ionization chambers. This further increases the range of applications the Barracuda can be used for and emphasis that it is truly an "All-In-One" device. If you prefer the traditional ionization chambers or if you want to have the possibility sometimes to "check with your own references" the Barracuda has everything you need. Almost all type of ionization chambers can be adapted and used with the Barracuda.

Powerful user-interface
A graphical display with the power of a handheld computer is used to present measured data, waveforms and other information in a clear and user-friendliness way. The Barracuda is easily controlled via the user-interface with the touch-sensitive display.

QA software for PC
The Barracuda can also be used with a PC, the QA software oRTIgo makes it possible to acquire, store and analyze measured data and waveforms. The oRTIgo software has predefined templates for all common tests used in standard QA. Based on the stored information about measuring conditions (generator set values, meter settings and other information) the Barracuda is prepared automatically for each exposure. Data are collected and stored quickly and reports can be created and printed instantly.

Wireless with Bluetooth
The Barracuda communicates wireless with Bluetooth. This minimizes the setup time and makes it very convenient when working with the Barracuda. No long cables, no more to step and stumble on or squeeze in doors. To use Barracuda with Bluetooth an optional USB adapter is required for the Barracuda.
For devices not supporting Bluetooth are RS232 and USB also available.

Prepared for the future
The Barracuda is a modular system. The cabinet can house up to six different modules, measuring independently of each other. The X-ray technology evolves rapidly and nobody can foresee what will be required from a measuring device in the future. We do not guarantee that the Barracuda already has "tomorrow's technology" but will provide it when required. The Barracuda has a place for it, allowing you to get new measuring capability in a very cost-effective way.
Accessories
Many accessories are available that further extends the use of the Barracuda:


mAs probes
- three different models are available:
MAS-1: Invasive mAs probe 0.1 - 2000 mA
MAS-2: Non-invasive, clamp-on, mAs probe 10-2000 mA
MAS-3: Non-invasive mAs probe 0.1 - 2000 mA
Dose detector - R100B dose detector for low dose rate measurements. Input dose to image intensifiers, scatter and lealage.
Range: 1 nGy/s - 76 mGy/s or 0.4 mR/h - 31 kR/h

Light detector - L100 can be used for checking the brightness of monitors and viewing boxes, and ambient light.
Range: 0.03 - 150 000 cd/m2 and 0.01 - 50 000 lx

CT chamber and CT phantom - Body and head CT phantom and CT probe, DCT10 RS, for CTDI measurements.
Range: 0.04 mGycm - 35 MGycm
 

CT Slice Probe - The CT-SD16 CT Slice Detector from RTI Electronics is a new and highly advanced detector for the evaluation of computed tomography systems. The CT-SD16 is designed to be used with the Barracuda X-ray multimeter and a PC running the Barracuda CT Slice Detector software. With the new probe and the software several important parameters can be evaluated at the same time such as the CT dose profile, table speed, CTDIscan *), and tube current variations.

 

Panoramic (OPG) holder - This holder is used to position the Barracuda detector when doing measurements on panoramic dental systems.
HVL stand - Adjustable stand for easy positioning of the Barracuda detectors. The stand can also be used when measuring horizontal and under-table tubes.
Ion chamber - optional ion chmaber Magna 1cc. It is designed especially for mammography but can also be used for radiography applications.
 BNT and TNT adapters - The adapters are used to connect different types of ionisation chambers to the Barracuda. Chambers with BNC/Banana connector can also be used but no adapter is needed.
Cases - Different cases for transportation and storage are available.
QA Software - The oRTIgo 2002 QA software and a PC can be used with Barracuda. The oRTIgo software has everything you need for QA on any type of X-ray system.

Free upgrades
New features are continuously added based on feedback from existing users. The new features are released and made available to all existing users. The updates are available free of charge on our website and are easily downloaded to the Barracuda.

For More Information


Specifications

General
The specifications below are valid for a typical Barracuda system. Note that the Barracuda is a modular design and can be purchased in many different configurations.

Barracuda Cabinet
The cabinet can house up to six different application modules. PC communication via Bluetooth, USB, or RS232. Handheld computer communication via Bluetooth or RS232.

Multi-Purpose Detector with Signal Extension Module
The Multi-Purpose Detector measures kVp, time, pulses, dose, dose rate, dose per pulse, pulse rate, HVL, total filtration and waveforms. Calibrations are available for radiography, mammography, and CT. The radiography calibrations also include fluoroscopy, dental and panoramic dental. The mammography calibrations include target/filter combinations Mo/Mo, Mo/Rh, Mo/Al, Rh/Rh, Rh/Al, W/Rh and W/Al.

Parameter
Range
Inaccuracy
kVp M
20 - 49 kV
±1.5 % or ±0.7 kV
kVp R/F, D
35 - 155 kV
±1.5 %
kVp CT
75 - 150 kV
±1.5 %
Irradiation time

0.1 ms - 2000 s
0 - 65535 pulses

±1 % or 0.5 ms
±1 pulse
Dose
0.1 µGy - >100 kGy
11 µR - >1100 kR
±5 %
Dose rate
0.2µGy/s - 350 mGy/s
12 µR/s - 36 R/s

±5 % or ±0.02 µGy/s
±5 % or ±0.14 mR/min

Total filtration
1.5 - 38 mm Al equiv.
±10 % or 0.3 mm
(60 - 120 kV, HF/DC)
Qick HVL
1.2 - 14 mm Al equiv.
±10 % or 0.2 mm

Electrometer Module
The electrometer module measures current, charge, and exposure time from the attached detector. The electrometer module accepts many existing RTI detectors and probes such as R100, R100B, mAs probes, light detector, CT probes as well as ionization chambers from other manufactures. Different models of electrometer modules are available; single channel with or without bias, twin channel without bias and a 1 channel wide-range with bias.

Parameter Range 1) Inaccuracy
Charge 50 fC - >100 mC ±1 % or ±12.5 fC
±0.5 % above 100 pC
Current

(wide-range)
2 pA - 10 µA
-2 pA - -4.8 µA
40 fA - 10 µA

±1 % or ±0.5 pA
±0.5 % above 100 pA
±1 % or ±4 fA
±0.5 % above 100 pA

Irrad. time 0.1 ms - 34000 s
1 - 65535 pulses
±1 % or ±0.5 ms
±1 pulse
Bias ±300 V +20/-10 V

R100B Dose Detector
The R100B dose detector measures dose and dose rate when connected to an electrometer module.

Parameter Range 1) Inaccuracy
Dose

0.10 nGy - >100 kGy
0.012 µR - >1100 kR

±5 %
Dose rate 1.0 nGy/s - 76 mGy/s
0.1 µR/s - 8.7 R/s
±5 % or ±0.25 nGy/s
±5 % or ±0.025 µR/s

1) The ranges specified is valid for a combination of modules.

Display Unit
The Barracuda requires either a handheld Palm compatible computer or a PC for a display device. The handheld uses the RTI QABrowser for simplicity and presentation of data. With PC, oRTIgo 2002 QA software is used for acquiring, storing of data and reporting. Waveforms can be measured both when using handheld computer and PC.

Handheld computer requirements Palm OS v3.5 or higher, 8 MB memory and connector compatible with Palm Tungsten T, T2,T3, m500, m505, and m515
Recommended model Tungsten T3
Interface Wireless Bluetooth, RS232
PC requirements Windows 95, NT, 98, Me, 2000 or XP
Interface Wireless Bluetooth, RS232 or USB

Optional probes and detectors
A wide range of optional probes and detectors can be used with the Barracuda. The following list gives measuring ranges for different probes/detectors when used with Barracuda.

Probe/Detector Range 1)
Invasive mAs probe, MAS-1 0.1 - 3000 mA, 0.001 mAs - 9999 mAs
Non-invasive mAs probe, MAS-2 10 - 4000 mA, 0.1 mAs - 9999 mAs
Non-invasive mAs probe, MAS-3 0.1 - 2000 mA, 0.01 mAs - 9999 mAs
Light detector, L100 0.03 - 72000 cd/m2
0.01 - 24000 lx
CT ionization chamber 4 µGycm - 35 MGycm
160 µGycm/s - 7 kGycm/s
1.2 Rcm/min - 34 MRcm/min
Ionization chamber, Magna 1 cc 5 µGy/s - 250 Gy/s
30 mR/min - 1500 kR/min

1) The ranges specified is valid for a combination of modules.

Other ionization chambers can be used with Barracuda. Adapter cables may be required.
Cases, HVL stand, HVL filters, dental panoramic holder, and adapter cables for ionization chambers with triaxial BNT and TNT connectors.

Physical Specifications

Cabinet
             

Weight
  Size

approx. 1000 g
155 x 135 x 62 mm
6.1" x 5.3" x 2.4"

Multi-Purpose Detector


Weight
  Size

appr. 250 g
122 x 55 x 14 mm
4.8" x 2.1" x 0.55"
Power 6 power alkaline batteries type LR6 or rechargeable NiMH (size AA), or an external power supply
Operation time Typically 5-6 h with NiMH (2100 mAh)
 