The Barracuda can be configured according to your own needs and requirements. This configurator will step you through the process to create a Barracuda system according to your specific needs.
Step #1 - Choose multimeter applications
The MPD (Multi-Purpose
Detector) is used for all modalities to measure kVp, exposure time, dose, dose
rate, dose/pulse, pulse rate, total filtration and HVL.
Please mark below the application(s) you want to have:
| R/F, dental and dental panoramic (OPG) | ![]() | ||
| Mammography | ![]() | ||
| CT (only kVp and time, CT dose requires a specific CT ion chamber) | ![]() |
||
Step #2 - Choose Additional Dose measurements
You may need an extra dose probe, solid state or ionsation chamber, for the following cases:
| R100B with calibration A for low dose rate (<200 nGy/s) applications | ![]() |
| Magna 1cc | Ion chmaber | ![]() |
|
| Cal B | Radiography | ||
| Cal D | Mammography | ||
If you make a choice in the section abowe, the electrometer module will be added to your Barracuda configuration.
CT dose, CTDI and CT Dose Profile
A CT ionisation chamber is neccessary to measure CT dose. An additional phantom is also required to measure CTDI (CT dose index).
If you made a choice in the
section abowe, the electrometer
module will be added to your Barracuda configuration.
| No CT phantom | |||
| Head Phantom | |||
| Body Phantom (incl. the Head Pahantom) | ![]() | ||
| Extra phantom adapter plug (one is included in the phantom) | ![]() | ||
| Case for CT phantom | ![]() |
||
Step #3 - Choose Additional Probes and Detectors
Other probes that can be used with the Barracuda are mAs probe and light detector.
mAs probes
Both invasive and non-invasive mAs probes are available.
| MAS-1: Invasive (0.1 mA - 2 A) | ||
| MAS-2B: Non-invasive (10 mA - 2 A) | ![]() |
|
| MAS-3: Non-invasive (0.1 mA - 2 A) | ![]() |
|
| I have already MAS-2B and I will use it | ![]() |
|
| I have already MAS-1, MAS-2, MAS-3 and I will use it |
If you made a choice in this section, the electrometer module will be added to your Barracuda configuration.
Light
detector
The light detector can measure
luminance and illuminance with use of different adapters. The most common
applications are checking monitors, viewing boxes and measuring the room light
(ambient light).
| L100 | ![]() |
| Adapter for illuminance (monitor, viewing box...) | ![]() | |
| Adapter for luminance (ambient light) | ![]() |
| I have already L100 and want to use it with Barracuda |
If you made a choice in this section, the electrometer module will be added to your Barracuda configuration.
Step #4 - Choose Stand, Holders and Filters
There are special stand/holders available for Multi-Purpose Detector that makes it easier to position the detector in various situations.
| No MPD & HVL Stand | |||
| MPD Holder & HVL Stand with support for 33 x 33 mm filters (Standard) | ![]() | ||
| MPD Holder & HVL Stand with support for 100 x 100 mm filters | ![]() | ||
| I don't have the old PMX-III HVL stand | |||
| I have already the PMX-III HVL-stand and need just an adpater for the Multi-Purpose Detector and support for 33 x 33 mm filters | ![]() | ||
| No additional filter holder | |||
| Addtional filter holder for 100 x 100 mm filters | ![]() | ||
| HVL filter kit 33x33 mm | ![]() | ||
| HVL filter kit 100 x 100 mm | ![]() |
||
| Al filters 2 pcs. 10 x 33 x 33 mm | ![]() |
||
| MPD holder for panoramic dental (OPG) | ![]() |
||
Step #5 - Choose Software
The Barracuda can be operated
from a handheld computer with Palm OS® running the QABrowser software or from
a PC with Windows operating system running the oRTIgo 2002.
QABrowser Software
| I don't want to use a Palm and I don't need the QABrowser software | |||
| Yes, I want to use a Palm and I need the QABrowser software for Palm handheld computer | ![]() |
||
oRTIgo
Software
The PC software oRTIgo is a QA program
that allows you automate your QA and service work.
Choose type of interface for the PC connection:
| RS-232 interface cable (8m) | ![]() | ||
| USB interface cable (5m) | |||
| USB interface extension cable (5m) | ![]() |
| Wireless - Bluetooth | ![]() |
Step #6
- Choose Handheld Computer
We support the following models:
| I am not going to use a handheld computer | ||
| I want to buy a handheld computer (indicate model below) |
| Palm Tungsten E2 (only this model is supplied by RTI) | ![]() |
||
| I have a handheld computer that I |